Frequently Asked Questions
If you’re installing a new cat 6 network, a network switch or router will be required. If installing a fiber network, a fiber switch will be required. A patch panel will be installed to make installing the switch easy and cost effective for long-term installations.
- CAT5: Out of the three types of cable we’ll be discussing, Category 5 is the most basic. Cat 5 cable is available in two varieties: Unshielded Twisted Pair (UTP), the type widely used in the United States, and Screened Twisted Pair (SCTP), which has shielding to provide a measure of extra protection against interference, but is rarely used outside of Europe. Cables belonging to Category 5 are either solid orstranded: Solid Cat 5 is more rigid, and the better choice if data needs to be transmitted over a long distance, while Stranded Cat 5 is very flexible and most likely to be used as patch cable. Cat 5 cable can support 10 or 100 Mbps Ethernet, and has a capability of up to 100MHz.
- CAT5e: Cat 5e (which stands for Category 5, enhanced) cable goes along the same lines as basic Cat 5, except that it fulfills higher standards of data transmission. While Cat 5 is common in existing cabling systems, Category 5e has almost entirely replaced it in new installations. Cat 5e can handle data transfer at 1000 Mbps, is suitable for Gigabit Ethernet, and experiences much lower levels of near-end crosstalk (NEXT) than Cat 5.
- CAT6: Of the three cable categories we’re discussing, Category 6 is the most advanced and provides the best performance. Just like Cat 5 and Cat 5e, Category 6 cable is typically made up of four twisted pairs of copper wire, but its capabilities far exceed those of other cable types because of one particular structural difference: a longitudinal separator. This separator isolates each of the four pairs of twisted wire from the others, which reduces crosstalk, allows for faster data transfer, and gives Category 6 cable twice the bandwidth of Cat 5! Cat 6 cable is ideal for supporting 10 Gigabit Ethernet, and is able to operate at up to 250 MHz. Since technology and standards are constantly evolving, Cat 6 is the wisest choice of cable when taking any possible future updates to your network into consideration. Not only is Category 6 cable future-safe, it is also backward-compatible with any previously-existing Cat 5 and Cat 5e cabling found in older installations.
Fiber offers higher data tranfer rates and longer distances and is frequently used for interconnecting buildings and data centers.
Depending on the type of installation, building inspectors require plenum rated cable in most high-rise buildings and is not required by single story facilities. Plenum rated cable is a low smoke, low toxicity cable that is required for fire-life safety with buildings. This is a preferred cable over PVC.
Depending on the type of installation, some drilling may be required to get the cables to their desired access points. Alternative options may be available. Ask your consultant for details.